Your personal consultant
Mon–Fri: 08:00–17:00

Winter and special concrete

Our range includes over 20 admixture formulas for concrete and mortars, adapted to various technological and climatic conditions. Each admixture is certified for quality and comes with detailed dosage recommendations and application guidelines.

Still have questions?

Your email address will not be published. 

Required fields are marked with *

Этот сайт защищен reCAPTCHA, и применяются Политика конфиденциальности и Условия использования Google.

Plasticizer and Accelerator with Antifreeze Effect
Acts as a hardening accelerator and setting intensifier, reducing curing time. Provides up to 20% strength gain at 1 day and up to 12% at 28 days.

Purpose:
Used as a plasticizer with antifreeze effect for concreting under direct freezing down to -7 °C, and with preheated aggregates down to -10 °C, with mandatory subsequent curing (the “thermos” method).

Application:
Add to the concrete (mortar) mix as a component together with mixing water. Stir before use. The amount of admixture is calculated according to the dosage. Further concreting or mortar application is carried out using standard technological procedures.

Dosage:
The admixture should be dosed for cement systems, concretes, and mortars in the form of a ready-to-use aqueous concentrate supplied in its original container, in the following amounts:

  • For direct freezing (down to -5 °C): from 3% of binder mass.
  • Under normal concreting conditions: from 1% of binder mass, together with mixing water through the water dispenser. Pre-mixing with water does not impair the quality of the admixture but requires adjustment of the consumption after dilution.

For mechanical dosing, it is best to add together with the mixing water through the water dispenser. Pre-dilution with water does not reduce admixture performance but requires recalculating consumption relative to the concentrate.

Recommendations:
The dosing container must be clean and provide precise volume measurement.

Safety Instructions:
Avoid ingestion or contact with food. In case of eye or skin contact, rinse thoroughly with water.

All rights reserved.

Complex plasticizer and accelerator additive for ready-mix and precast concretes. The additive increases both early and ultimate strength of concretes and mortars, improves mix fluidity, and accelerates concrete hardening. It helps reduce energy consumption during steam curing (TVO/TO) of reinforced concrete and heating of ready-mix concrete.

Purpose:
Used to increase the workability of concrete mixes from P1 to P4 at ambient temperatures down to −5 °C, while ensuring the designed concrete performance.

Usage:
Add to the concrete or mortar mix together with mixing water. Stir thoroughly before use. The amount of additive is calculated according to the dosage (see below). Subsequent concreting or use of mortars is carried out following standard technological procedures.

Dosage:
The additive should be dosed for cement systems, concretes, and mortars in the form of a ready-to-use aqueous concentrate in the container in which it is sold, at a rate of:

  • From 1 L per 100 kg of cement.

Optimal dosage should be determined in the laboratory for each specific technological case.

For mechanical dosing, it is preferable to introduce it together with the mixing water using a water dispenser. Pre-mixing with water does not reduce the additive’s quality but requires adjustment of the additive amount after dilution.

Recommendations:
The dosing container must be clean and have a precisely fixed volume.

Safety rules:
Avoid contact of the additive with the mouth or food products. In case of contact with eyes or skin, rinse thoroughly with water.

Superplasticizer and accelerator additive with antifreeze effect. It improves concrete mix fluidity, accelerates hardening kinetics, and increases early strength by up to 35% at 1 day and up to 20% at 28 days, compared to similar classified additives.

Purpose:
Used for the preparation of concrete mixes (ready-mix, precast, road) as a superplasticizer with antifreeze effect down to −15 °C.

Usage:
Add to the concrete or mortar mix together with mixing water. Stir thoroughly before use. The amount of additive is calculated according to the dosage (see below). Subsequent concreting or use of mortars is carried out following standard technological procedures.

Dosage:
The additive should be dosed for cement systems, concretes, and mortars in the form of a ready-to-use aqueous concentrate in the container in which it is sold, in the following quantities:

  • For precast reinforced concrete: from 0.7 % by weight of binder.
  • For conventional ready-mix concrete in the cold season (+10 °C and below) with subsequent curing: from 1 % by weight of binder.
  • For direct freezing of concrete down to −10 °C: from 2 % by weight of binder.

Optimal dosage should be determined in the laboratory for each specific technological case.

For mechanical dosing, it is preferable to introduce it together with the mixing water using a water dispenser. Pre-mixing with water does not reduce the additive’s quality but requires adjustment of the additive amount after dilution.

Recommendations:
The dosing container must be clean and have a precisely fixed volume.

Safety rules:
Avoid contact of the additive with the mouth or food products. In case of contact with eyes or skin, rinse thoroughly with water.

Antifreeze additive for mortars, enabling masonry work at temperatures down to −15 °C using the “thermos” method. It increases the “workable life” of fresh mortar mixtures, ensures further strength development, and allows the mortar to reach its designed strength grade.

Purpose:
Used for preparing mortar mixes as a plasticizer with antifreeze effect down to −10 °C, and down to −15 °C when applying the “thermos” method.

Usage:
Add to the mortar mix together with mixing water. Stir thoroughly before use. The amount of additive is calculated according to the dosage. Subsequent masonry or use of mortars is carried out following standard technological procedures.

Dosage:
The additive should be dosed for cement systems, concretes, and mortars in the form of a ready-to-use aqueous concentrate in the container in which it is sold, in the following quantities:

  • For precast reinforced concrete: from 0.7 % by weight of binder.
  • For conventional ready-mix concrete in the cold season (+10 °C and below) with subsequent curing: from 1 % by weight of binder.
  • For direct freezing of concrete down to −10 °C: from 2 % by weight of binder.

Optimal dosage should be determined in the laboratory for each specific technological case.

Recommendations:
The dosing container must be clean and have a precisely fixed volume.

Safety rules:
Avoid contact of the additive with the mouth or food products. In case of contact with eyes or skin, rinse thoroughly with water.

Universal Admixture for Precast and Ready-Mix Concrete
Effective in the temperature range from -5 °C to +35 °C, ensuring high early strength of concrete, improving the quality of construction works and accelerating the pace of building.

Purpose:
Used in the production of cement-based concrete and mortar mixtures, including industrial floors and heated floors, as a superplasticizer and hardening accelerator.

Application:
Mix before use. Add to the concrete (mortar) mix together with the mixing water.

Dosage:
The admixture should be dosed for cement systems, concretes, and mortars in the form of the ready-to-use aqueous concentrate supplied in its original container, in the following amounts:

  • For direct concrete freezing: 1.2% by binder mass;
  • For precast reinforced concrete: 0.65% by binder mass;
  • For ready-mix concrete in the cold season with subsequent curing: 0.8% by binder mass.

The optimum dosage should be determined in the laboratory for each specific technological case.
For mechanical dosing, it is recommended to add together with the mixing water through the water dispenser. Pre-mixing with water does not reduce admixture performance but requires consideration of consumption after dilution.

Recommendations:
The dosing container must be clean and provide accurate volume measurement.

Safety Instructions:
Avoid ingestion or contact with food. In case of eye or skin contact, rinse thoroughly with water.

Plasticizing and accelerating admixture for the production of reinforced concrete elements using the extrusion method.

Purpose:
Used for the production of reinforced concrete elements by the slipform extrusion method. Provides the optimal consistency of the concrete mix for stable extruder operation, accelerates the hardening process, increases early and final strength, improves the surface quality of finished products, and ensures their geometric stability. Contributes to cement and energy savings.

Application:
The admixture is introduced into the concrete mix as a component together with the mixing water. Mix thoroughly before use.

Dosage:
The admixture should be dosed as a ready-to-use water-based concentrate supplied in the manufacturer’s packaging, in the amount of:
from 0.6 L per 100 kg of cement, depending on the required plasticity and setting speed.

The optimal dosage should be determined in the laboratory for each specific technological case.
For mechanical dosing, it is recommended to feed the admixture together with the mixing water through a water dispenser. Pre-mixing with water does not affect the quality of the admixture.

Recommendations:
The dosing container must be clean and have a precisely fixed dosing volume.

Safety instructions:
Avoid contact of the admixture with the mouth and food products. In case of contact with eyes or skin, rinse thoroughly with water.

Your personal consultant
Mon–Fri: 08:00–17:00